YZ series Submersible Pump Potential Fault and Solving
YZ Submersible pump Potential fault and solving
Fault | Reason | Solution |
Water can not be pumped out with pointer of pressure gauge tempestuously flouncing. | 1. Water exit has been blocked. 2. Air leakage is happening to pipeline and meters. | 1. Have the silt discharged. 2.Have the air leakage location screwed down or blocked. |
The pump can not pump out water. | 1.Water-in mouth of the pump has been higher than liquid level. 2. Rotating direction is incorrect. | 1.Have the liquid level raised or decrease the pump height. 2.Inspect the rotating direction of the motor. |
The water exit is indicated having pressure by the pressure gauge but no water comes out. | 1.The resistance of water output is too big. 2. The impeller is blocked. 3. Rotating speed is not enough. | 1. Have the pipeline checked. 2. Have the impeller washed. 3. Have the rotating speed increased. |
Flux is too low. | 1.The pump is blocked. 2.The rotating speed is not enough. 3. The impeller is too much blocked | 1.Have the pump and pipeline washed. 2. Have the rotating speed increased. 3. Have the impeller replaced |
The pump has consumed too much power. | 1. Water supplying to the pump is too small (or wholly cut off). 2. The impeller is worn out. | 1. Open the gate valve at exit pipe. 2. Have the impeller replaced. |
The bearing is overheated. | 1.The bearing lacks oil. 2.There is filth accumulated inside the bearing or bearing is broken | 1.Have lubricating grease added. 2.Have the bearing washed or replaced. |